GEB 11.1V 200Ah (2.22kWh) Cylindrical Lithium-ion Battery Pack with 100A-150A BMS

Heavy-duty 11.1V 200Ah (2.22kWh) 3S cylindrical lithium-ion battery pack (Approx. 16.8kg) with integrated 100A continuous / 150A peak smart BMS, pure nickel busbars, and M8/Anderson terminals for industrial robots, marine equipment, and mobile DC power.

B2B Engineering Review & Pricing

Direct manufacturer supply, custom BMS telemetry, and CAD fit validation for OEM/ODM projects.

✔ Response target: Target response within 12 business hours during business hours; timing varies by inquiry complexity and working hours.
✔ Typical Lead Time: 7–10 business days for prototypes; 15–20 business days for mass production after final specification approval. Final timing is confirmed after tooling, testing, and order review.
✔ Shipping documentation: Applicable UN38.3 test documentation, MSDS/SDS, CE and Class 9 dangerous-goods requirements are confirmed per selected configuration and shipment.

Product Details

Direct Answer / Engineering Summary

The GEB 11.1V 200Ah (2.22kWh) Cylindrical Lithium-ion Battery Pack is an industrial high-capacity motive and energy storage power system engineered with a 3S cylindrical cell architecture. Delivering a verified 11.1V nominal operating voltage and 200Ah rated capacity (2,220Wh / 2.22kWh total energy), this pack is equipped with a heavy-duty 100A continuous (150A peak pulse) smart BMS featuring multi-tier hardware protections (OVP, UVP, OCP, SCP, OTP). Assembled with laser-welded pure nickel busbars, high-temperature structural cell brackets, and internal epoxy insulating baffles, it weighs Approx. 16.8 kg and delivers rock-solid DC power for mobile robotics, marine low-voltage DC grids, and critical field workstations.

Engineering Overview

Product Overview

The GEB 11.1V 200Ah (2.22kWh) Lithium-ion Battery Pack solves high-drain continuous energy requirements where standard lead-acid batteries present prohibitive weight and space penalties. Providing 2.22kWh usable energy at roughly one-third the weight of equivalent AGM/Gel systems, it integrates Grade-A high-capacity cylindrical cells grouped under strict barcode impedance sorting. Measuring 330 × 220 × 160 mm and protected by a flame-retardant heavy-gauge casing with dual M8 brass post terminals and Anderson SB120 connectors, this power plant easily handles continuous 1100W loads. The internal active BMS balances series strings automatically during top-of-charge CC/CV regulation.

Quick Reference

Product Specifications

Feature / Attribute Technical Specification
Battery Chemistry Lithium-ion (NMC Cylindrical Matrix / 3S Architecture)
Nominal Voltage & Energy 11.1V Nominal (12V class) / 200Ah (2,220Wh / 2.22kWh)
Integrated Smart BMS 100A Continuous Discharge / 150A Peak Surge (≤ 5s)
Physical Dimensions (L×W×H) 330 × 220 × 160 mm (±3.0mm)
Total Pack Weight Approx. 16.8 kg (±0.5kg)
Power Terminals & Wiring M8 Brass Screw Terminals + Anderson SB120 High-Current Port
Target Applications Industrial AGVs, mobile pipeline inspection robots, marine DC backup, off-grid telemetry towers
Enclosure Construction Heavy-duty epoxy structural framing + Flame-retardant industrial PVC shrink wrap
Service Life / Endurance ≥ 800–1,200 cycles (@ 80% DoD, 25°C)
Engineering Data

Technical Specifications

Parameter Value Test Conditions & Engineering Tolerances
Nominal Operating Voltage 11.1V (3S Li-ion) Standard measurement @ 25°C, 0.2C discharge rate
Upper Voltage / Charge Cutoff 12.60V ± 0.05V Dedicated 3S CC/CV lithium charger, 0.02C termination
Discharge Lower Cutoff 9.00V ± 0.10V Automatic BMS hardware low-voltage threshold (3.0V/cell)
Recommended Charging Current 20A – 40A (0.1C – 0.2C) Maximizes cell cycle life and thermal uniformity
Maximum Continuous Charge 60A (0.3C) Fast-charge limit under ambient ventilation
Internal DC Impedance ≤ 18 mΩ Fully assembled pack measured at M8 terminals
Operating Temperature Range Charge: 0~45°C | Discharge: -20~60°C Storage: 15~25°C (50%–60% SoC storage)
Engineering & Integration

Integration & Operational Boundary Conditions

Charger Specification: Always connect a dedicated 12.6V CC/CV lithium-ion charger. Do not use legacy lead-acid chargers featuring desulfation pulses or float voltages exceeding 12.6V, as this will trigger the BMS over-voltage latch.

Mounting & Vibration Isolation: When installing on mobile automated platforms or marine craft, secure the battery pack within a rigid battery tray using shock-absorbent neoprene pads. Do not puncture or apply direct clamping pressure on the outer shrink wrap.

Series / Parallel Stacking Constraints: This pack is designed for stand-alone 12V DC service or parallel capacity expansion (up to 2 units in parallel of identical batch and voltage). Connecting packs in series for 24V/36V systems requires factory-customized high-voltage BMS configurations.

Engineering Validation

Equipment Compatibility & Engineering Fit Check

Before deploying GEB 11.1V 200Ah (2.22kWh) Cylindrical Lithium-ion Battery Pack with 100A-150A BMS, verify these verified electrical and mechanical boundary requirements:

☑
Voltage & Charge Cutoff: Nominal 11.1V (charging CC/CV cutoff at 12.6V); confirm charger algorithm strictly matches this chemistry.
☑
Capacity & Energy Budget: Rated at 200Ah; verify system run-time calculations under planned discharge currents.
☑
Physical Envelope: Specified at 330 × 220 × 160 mm (±3.0mm); allow 5–10mm buffer in battery tray for expansion and lead harness.
☑
Cycle Reliability: Verified for ≥ 800–1,200 cycles (@ 80% DoD, 25°C) under controlled DOD and thermal management.
💡 Custom Engineering Fit: Contact our Shenzhen engineering team to verify CAD models, custom wire leads, or BMS CANbus telemetry for this product.
Operational Suitability

Operational Boundary Conditions

✔ Recommended Fit & Use Cases:

  • Electronic devices and OEM packs matched with 11.1V / 200Ah power curves.
  • Commercial designs requiring high volumetric energy density and predictable discharge curves.
  • Projects requiring batch consistency with automated barcode impedance sorting.

⚠ Operational Constraints & Limits:

  • Do not discharge below minimum cutoff voltage or charge beyond 12.6V.
  • Maintain operational surface temperature within -20°C to +60°C discharge (0°C to +45°C charge).
  • Ensure connector polarity and pin assignment match system schematics prior to initial power-up.
First-Party Standards

First-Party Manufacturing SOP & Export Compliance

🏭 Automated Grading & Matching Cells classified via automated OCV/ACIR sorting (ΔV ≤ 2–3mV, ΔR ≤ 1.2mΩ) for tight pack balance.
🔬 Joint Integrity & Testing Laser or ultrasonic busbar welding with destructive pull test validation ≥ 5.0–8.0 kgf per terminal.
📦 Full Cycle Aging Verification 100% full charge-discharge cycle screening and thermal imaging prior to warehouse dispatch.
🌐 Export & Regulatory Clearance Supplied with certified UN38.3 test summaries, MSDS, 1.2m drop reports, and Class 9 DG shipping documentation.
Turnaround: 7–10 days prototypes; 15–20 days mass production per custom tooling requirements. View Verified Manufacturing Equipment & Testing Facility →

⚙ Engineering FAQ & B2B Procurement Specifications

What is the turnaround time for custom battery pack prototypes and mass production for GEB 11.1V 200Ah (2.22kWh) Cylindrical Lithium-ion Battery Pack with 100A-150A BMS?
Custom prototype development typically requires 7 to 10 business days after CAD drawing approval and technical specification freeze. Commercial mass production turnaround is typically 15 to 20 business days. Standard OEM minimum order quantities (MOQ) start at 50 to 100 units depending on cell chemistry, custom mold tooling, and casing complexity.
Does GEB provide UN38.3 test summaries, MSDS, and Class 9 dangerous goods export compliance?
Yes. General Electronics Technology (GEB) provides complete first-party compliance verification for all industrial battery packs, including UN38.3 test reports, 1.2m drop test appraisal certificates, MSDS/SDS sheets, and certified dangerous goods packaging compliant with IATA air transport and IMDG maritime shipping regulations.
What smart telemetry protocols and BMS protection features are supported?
Our custom smart BMS architectures support industry-standard communication protocols including UAVCAN, CANbus 2.0B, SMBus, UART, and RS485. Integrated hardware protections include multi-tier over-voltage, over-discharge, continuous over-current, short-circuit, and dual-channel NTC thermal cutoff safeties with active cell balancing options.
What are the recommended continuous and peak burst discharge margins?
To maximize lifecycle endurance and electrochemical stability, we recommend designing with a 15% to 20% continuous discharge headroom margin under typical operating loads. Peak burst discharge ratings should strictly adhere to specified duration windows (typically ≤10 seconds) while ensuring pack operating temperatures remain below 65°C.

Request Engineering Review & Custom Battery Quote

Submit your technical requirements, continuous/peak discharge loads, or enclosure dimensions for an immediate engineering assessment.

B2B Product Inquiry