22.2V 6S 8000mAh 25C High-Rate LiPo for VTOL & Inspection UAVs
Industrial-grade 22.2V 6S 8000mAh 25C LiPo battery pack (177.6Wh, Approx. 1080g) engineered for hybrid VTOL platforms, security surveillance UAVs, and infrastructure inspection drones requiring sustained 200A discharge.
B2B Engineering Review & Pricing
Direct manufacturer supply, custom BMS telemetry, and CAD fit validation for OEM/ODM projects.
Product Details
The 22.2V 6S 8000mAh 25C High-Rate LiPo for VTOL & Inspection UAVs is a professional-grade high C-rate Lithium Polymer (LiPo) solution delivering a verified 22.2V nominal working voltage and 8,000mAh rated capacity (177.6Wh) with a continuous discharge capability of 25C (200A) and peak burst of 50C (400A). Engineered for commercial multirotor drones, hybrid eVTOL systems, and aerial survey platforms, this high-rate pack utilizes ultra-low internal resistance foil stacking and reinforced terminal tabs to sustain demanding continuous discharge loads with minimal voltage sag and controlled thermal rise.
Product Overview
The 22.2V 6S 8000mAh 25C High-Rate LiPo for VTOL & Inspection UAVs is engineered for commercial inspection platforms, security patrol multirotors, and long-endurance hybrid VTOL airframes. Providing 22.2V nominal voltage and 8000mAh rated capacity (177.6Wh total energy), this pack delivers a consistent 25C continuous discharge rate (200A output) with ultra-low internal impedance and extended flight margins. Housed in a flame-retardant heat-shrink sleeve with aluminum heat-shielding armor measuring 52 × 65 × 165 mm and weighing Approx. 1,080g (1.08kg), it features an XT90 connector and standard JST-XH 6S balancing lead.
Product Specifications
| Feature / Attribute | Technical Specification |
|---|---|
| Nominal Voltage & Energy | 22.2V (6S LiPo) / 8000mAh (177.6Wh) |
| Continuous Discharge Rating | 25C Continuous (200A) |
| Peak Pulse Discharge Rating | 50C Peak Pulse (≤ 5s, 400A) |
| Physical Dimensions & Weight | Approx. 52 × 65 × 165 mm / Approx. 1,080g (1.08kg) |
| Main Terminals | XT90 Connector / JST-XH 6S Balance Lead |
| Charge Cutoff / Discharge Cutoff | 25.2V (4.20V/cell) / 18.0V (3.00V/cell) |
| Cycle Endurance | ≥ 300–500 Heavy-Duty Flight Cycles (@ 80% DoD) |
Technical Specifications
| Parameter | Value | Test Conditions & Tolerances |
|---|---|---|
| Nominal Voltage Rating | 22.2V | Standard measurement @ 25°C |
| Charge Cutoff Voltage | 25.2V (4.20V per cell ±0.02V) | CC/CV smart balance charging mode |
| Discharge Cutoff Limit | 18.0V (3.00V per cell, telemetry alarm 3.30V–3.50V) | Flight controller telemetry alarm threshold |
| Internal AC Resistance (1kHz) | ≤ 1.5–2.5 mΩ per cell | 1kHz AC test @ 25°C fully charged |
| Operating Temperature Range | Charge: 0~45°C | Discharge: -20~60°C | Storage: 15~25°C (3.80V–3.85V/cell) |
Integration & Operational Boundary Conditions
Operating Temperature Envelope: Standard charge operating range is 0°C to 45°C; continuous discharge operating range is -20°C to 60°C. Long-term storage target should be maintained at 3.80V–3.85V per cell (approx. 40%–50% SoC) in a dry, climate-controlled environment.
BMS Protection Architecture: Compatible with custom smart BMS integrations supporting CANbus 2.0B, SMBus, UART, and RS485 telemetry protocols. Factory cutoff thresholds protect against over-charge, over-discharge, short-circuit, and cell thermal runaway.
B2B Procurement & Lead Times: Available for wholesale OEM/ODM procurement. Typical prototype sampling takes 7–10 business days, with mass production scaling within 15–20 business days. Standard Class 9 dangerous goods export packaging and UN38.3 test summaries provided with every shipment.
Equipment Compatibility & Engineering Fit Check
Before deploying 22.2V 6S 8000mAh 25C High-Rate LiPo for VTOL & Inspection UAVs, verify these verified electrical and mechanical boundary requirements:
Operational Boundary Conditions
✔ Recommended Fit & Use Cases:
- Industrial UAVs, FPV platforms, and robotics requiring rapid burst response at 22.2V.
- Flight missions needing high energy density and stable voltage plateaus under heavy payload draw.
- Applications demanding verified Class 9 / UN38.3 compliance for commercial field logistics.
⚠ Operational Constraints & Limits:
- Do not discharge below minimum cutoff voltage or charge beyond 25.2V.
- Maintain operational surface temperature within -20°C to +60°C discharge (0°C to +45°C charge).
- Ensure connector polarity and pin assignment match system schematics prior to initial power-up.
First-Party Manufacturing SOP & Export Compliance
Technical Whitepapers & Engineering Guides
6S vs 12S LiPo Battery for Drones: Voltage, Current, Weight, and Flight Time
Comprehensive engineering analysis on wiring resistive losses (I²R), ESC compatibility, and payload endurance trade-offs.
Drone Battery Capacity Guide: How Many mAh and Wh Does Your UAV Need?
Step-by-step formula to calculate power budget, payload weight, C-rate margins, and usable flight minutes.
LiPo vs Li-ion Battery for Drones: Which Is Better for Commercial UAVs?
Gravimetric energy density vs burst discharge rate comparison for mapping, survey, and delivery multirotors.
