GEB 3.6V 2000mAh AA Ni-MH Rechargeable Battery Pack (3S Pack for Solar & Backup)
Industrial 3.6V 2000mAh AA Ni-MH rechargeable battery pack (3S pack, 7.2Wh, Approx. 85g) featuring zero memory effect, pre-wired leads, and 500+ cycles for solar lawn lighting, emergency luminaires, and memory backup.
B2B Engineering Review & Pricing
Direct manufacturer supply, custom BMS telemetry, and CAD fit validation for OEM/ODM projects.
Product Details
The GEB 3.6V 2000mAh AA Ni-MH Rechargeable Battery Pack (3S Pack for Solar & Backup) is an industrial Nickel-Metal Hydride power pack constructed from three matched AA cylindrical cells in series (3S1P). Providing a verified 3.6V nominal working voltage and 2,000mAh rated capacity (7.2Wh energy), this pack is engineered for high cycle endurance (≥ 500–1,000 cycles under IEC standards) with zero memory effect. Assembled with precision spot-welded nickel tabs, built-in PTC over-current protection, and pre-attached UL1007 wire leads, it delivers dependable standby and cyclic power for solar outdoor lighting, emergency exit signs, remote telemetry sensors, and PCB memory retention.
Product Overview
The GEB 3.6V 2000mAh AA Ni-MH Battery Pack offers an inherently safe, environmentally compliant alternative to legacy Nickel-Cadmium (Ni-Cd) packs while delivering more than double the volumetric energy density. Built from Grade-A AA cells (14500 cylindrical size) arranged in an inline flat configuration measuring 43.5 × 14.5 × 50.5 mm and weighing Approx. 85g, it is encased in protective blue PVC heat-shrink tubing. Each string includes an integrated positive temperature coefficient (PTC) thermistor that automatically throttles current under external short-circuit events, resetting once the fault clears.
Product Specifications
| Feature / Attribute | Technical Specification |
|---|---|
| Battery Chemistry | Nickel-Metal Hydride (Ni-MH Rechargeable) |
| Configuration | 3S1P (3 × AA Cylindrical Cells in Series) |
| Nominal Voltage & Capacity | 3.6V / 2000mAh (7.2Wh) |
| Physical Dimensions (Inline Flat) | 43.5 × 14.5 × 50.5 mm (±1.0mm) |
| Pack Weight | Approx. 85 g (±3g) |
| Standard Continuous Discharge | 1.0C Continuous (2000mA continuous load) |
| Peak Pulse Discharge | 2.0C Pulse (4000mA ≤ 5 seconds) |
| Lead Wires & Terminals | UL1007 22AWG Leads (100mm) / Optional JST-PH, JST-XH, or Molex Connector |
| Target Applications | Solar pathway & garden lighting, emergency lighting luminaires, smart water meters, memory backup |
| Cycle Endurance | ≥ 500–1,000 cycles (@ IEC 61951-2 standards) |
Technical Specifications
| Parameter | Value | Test Conditions & Engineering Tolerances |
|---|---|---|
| Nominal Operating Voltage | 3.6V | Standard measurement @ 25°C, 0.2C rate |
| Upper Charge Cutoff Voltage | 4.35V – 4.50V | -ΔV cutoff (15–30mV/pack) or 0.1C (200mA) 15h timed charge |
| Discharge Lower Cutoff | 3.00V ± 0.05V | 1.00V/cell minimum safety threshold under load |
| Internal AC Resistance (1kHz) | ≤ 60–90 mΩ (Pack) | 1kHz AC impedance test @ 25°C fully charged |
| Standard Charging Current | 0.1C (200mA) × 14–16 hours | Safe continuous trickle / standard charging |
| Fast Charging Current | 0.5C (1000mA) with -ΔV cutoff | Smart charger with temperature sensor |
| Operating Temperature Range | Charge: 0~45°C | Discharge: -10~60°C | Storage: -10~35°C (40%~60% SoC storage) |
Integration & System Design Guidelines
Solar Panel Matching & Charging: When deploying in solar garden lighting fixtures, ensure the solar charge controller maintains a trickle charge current of 0.05C–0.1C (100mA–200mA) and prevents overcharge voltage from exceeding 4.50V across the 3S pack.
Over-Discharge Safeguard: Disconnecting loads when pack voltage drops to 3.00V (1.00V/cell) is mandatory. Operating below 2.4V (0.8V/cell) causes cell reversal, venting, and premature failure.
Storage & Self-Discharge: Store in a cool, dry location at 40%–60% state of charge. Ni-MH chemistry maintains an open circuit voltage around 1.25V–1.28V per cell (3.75V–3.85V for 3S pack) when healthy. Refresh every 90–120 days during prolonged warehouse storage.
Equipment Compatibility & Engineering Fit Check
Before deploying GEB 3.6V 2000mAh AA Ni-MH Rechargeable Battery Pack (3S Pack for Solar & Backup), verify these verified electrical and mechanical boundary requirements:
Operational Boundary Conditions
✔ Recommended Fit & Use Cases:
- Emergency lighting units, exit signs, solar garden fixtures, and industrial backup systems requiring 3.6V / 2000mAh.
- Applications requiring long-term continuous trickle charging and deep over-discharge resilience.
- Export projects benefiting from non-Class-9 general cargo air and sea freight logistics.
⚠ Operational Constraints & Limits:
- Do not use Li-ion CC/CV chargers: Charge only with Ni-Cd/Ni-MH constant-current (-ΔV / dT/dt) or rated trickle chargers.
- Maintain operating temperature within -20°C to +60°C discharge (0°C to +45°C standard / +55°C trickle charge).
- Ensure connector polarity and pin assignment match system schematics prior to initial power-up.
First-Party Manufacturing SOP & Export Compliance
Technical Whitepapers & Engineering Guides
Lithium Battery Quality Control Checklist for B2B Projects
15-point factory testing protocol covering automated cell grading, delta IR matching, spot-weld pull tests, and aging SOP.
LiPo Battery Shipping Documents: What Importers Should Prepare
Class 9 export compliance, UN38.3 test summaries, MSDS/SDS validation, and maritime/air cargo dangerous goods SOP.
Precautions for Custom Polymer Lithium Batteries: OEM Engineering & Design Guide
Key precautions for custom lithium polymer (pouch) battery packs: mechanical swelling allowances, tab sealing integrity, PCM parameters, and thermal safety.